Fireplace Inserts for Sherman Oaks Rental Properties

Book Fireplace Inserts

What the Owner Gets

Many owners retire wood burning in their rentals and fit gas inserts instead: no ash, no logs stacked on a balcony, and a sealed box the tenant runs with a switch. The insert vents up its own stainless liner, so cracked clay tiles stop mattering. Fitted into a fireplace the unit already has, the range here is $2,650 to $5,300, set by unit size, liner length and gas line work. We arrange the permit and its sign-off.

Wood burning retired in favor of gas
Stainless liner up the old flue
Gas line with a valve in reach
Opening measured before a unit is chosen
Permit and final sign-off arranged
Owner's manual filed with the unit

Why Landlords Convert to Gas Inserts

An open wood fireplace in a rental is a risk the owner cannot supervise. The tenant chooses what to burn, how big to build it and whether to leave it going overnight. Embers land on rugs. The flue needs sweeping on a schedule someone has to manage. And in the LA basin, no burn days under South Coast AQMD rules mean a tenant may not be allowed to use it on the coldest nights anyway. A gas insert removes most of that. It is a closed metal unit fitted inside the existing firebox, with a glass front, its own burner and its own vent pipe running up the old flue to the top. The tenant gets heat and a flame at the touch of a switch or remote. The owner gets a unit with no ash, no wood, no sweeping and a much smaller list of things that can go wrong.

Converting an existing wood opening to a gas insert costs $2,650 to $5,300 installed, including the liner up the flue and the trim around the face. Where a job lands in that range turns on opening size, which model is picked, chimney height and the distance the gas line must run to reach the firebox. If a unit has no fireplace and the owner wants to add one, a direct vent unit vented through an outside wall comes to $4,250 to $8,500. Each install includes the gas connection checked for leaks, the liner and the trim, so the price is the full price for a working unit. We can add a wall switch or a remote, and the tenant is shown how to use both. For a building converting in stages, each unit is quoted the same way, so the owner can budget a few units each year. Units that keep their wood fireplace are left on the sweep schedule.

Converting a Building in Stages

Few owners convert every unit at once. The usual plan is to do each unit at turnover, when it is empty and the work does not disturb a tenant, and to keep a list of which units are done and which still burn wood. We keep that list with you. Each install is written up with the unit, the model and serial number, the liner, the gas connection and the date, and the manual goes into the unit file. For condo buildings, the association often has a say in what can go into a shared chimney and what can run through a common roof, so we write the scope in a way a board can approve and give it the technical detail it asks for. Where the association has a list of approved models, we work from it.

Before any insert goes in, we inspect the chimney it will vent through. A cracked flue or a loose top still matters with gas, and the insert price assumes the chimney above it is sound enough to carry the liner and cap. If it is not, the scope says what has to happen first. Once installed, a gas insert belongs on the yearly gas service list with the other units, and we add it to your building log so it is not forgotten. When a unit already has an old insert, we look at its age and its liner before deciding whether to service or replace it. The old firebox is cleaned and checked before the insert goes in. Send us the address, the unit and when it will be empty, and we will set a visit to measure.

How Spalding Chimney Group Works With Landlords

Use, Hold, Repair

Every item tells the owner whether the unit can keep using it

Tenant Windows

Arrival windows agreed so notice can go out

Priced by Line

Approve urgent items now, plan the rest

Sign-Off Notes

Dated photos for each unit file

More Work Owners and Managers Order

Chimney Sweep

Flues swept between tenancies or on a yearly cycle, with the buildup level logged against the unit number.

Read more

Chimney Inspection

NFPA 211 Level 1 or Level 2 checks for rental units, written up per unit so an owner, manager or board can file them.

Read more

Chimney Repair

Cracked masonry, worn liners and loose caps on rental chimneys, scoped line by line so an owner can budget each fix.

Read more

Fireplace Inspection

Firebox, damper, hearth and mantel spacing looked over inside the unit, with any factory label photographed for the file.

Read more

Fireplace Repair

Panels, firebrick, dampers and hearths put right in occupied units, booked through the manager and closed with photos.

Read more

Chimney Level 2 Inspection

Recorded video up every flue, plus attic and roof sections, for turnover, a purchase, an insurer request or storm damage.

Read more

Chimney Cap Installation

Stainless caps with a spark screen fitted to each flue on a rental roof, photographed and logged for the owner and insurer.

Read more

Chimney Flashing Repair

Roof-line water at the chimney traced and stopped, with the source and the fix written up for the property file.

Read more

Chimney Masonry Repair

Open mortar joints, flaking faces and quake cracks on rental chimneys, priced by line so an owner can phase the work.

Read more

Chimney Rebuilds

Leaning or loose stacks taken down and rebuilt, with the permit and tenant notice built into the schedule.

Read more

Fireplace Cleaning

Firebox, glass doors and surround cleaned at turnover, so the next tenant moves in to a fireplace that looks cared for.

Read more

Gas Fireplace Cleaning

Burners, pilots and glass serviced across a building's gas units, with one dated service line per unit for the records.

Read more

Gas Fireplace Repair

Pilots that drop out, failed igniters and dead valves traced in occupied units, with parts and waits stated up front.

Read more

Fireplace Remodel

Surrounds, mantels and hearths renewed between tenancies, laid out around clearance rules and the local permit.

Read more

Pellet Stove Repair

Pellet units that jam, misfire or shut down traced and repaired, with the model plate recorded for the unit file.

Read more

Wood Stove Repair

Gaskets, baffles, firebrick and pipe on rental wood stoves, plus clearances measured against the maker's label.

Read more

Gas Logs

Gas log sets for rental fireplaces that tenants light with a key or a switch, with no firewood to store.

Read more

Chimney Seismic Retrofit

Old brick chimneys on rental buildings braced or cut back to lower the risk of falling masonry in a strong quake.

Read more

Chimney Crown Repair

Cracked or flat chimney tops sealed or recast, so rain stops soaking the brick on rental roofs nobody watches.

Read more

Dryer Vent Cleaning

Lint cleared from dryer ducts in rental units and laundry rooms, with airflow at the outside hood logged per unit.

Read more

Chimney Liner Installation

Stainless liners fitted where clay tile has cracked, so a rental flue can be used again and the record shows why.

Read more

Chimney Leak Repair

Tenant-reported water at the chimney traced to where it really enters, then sealed and photographed for the owner.

Read more

Chimney Waterproofing

Rental chimney brick sealed against rain with a repellent that still lets it dry, once every repair is finished.

Read more

Chimney Damper Repair

Rusted, jammed or warped dampers in rental fireplaces repaired or swapped, so a unit is not losing heat all winter.

Read more

Chimney Chase Cover

Rusted or sagging metal tops on framed chimney chases replaced in stainless, so rain stops reaching the wood below.

Read more
Send Building Details